Dispelling Loop Myths: Wire Gauge
You've probably heard that wire gauge doesn't matter in loop design, but is that the truth?

Open as a PDF

Can loop performance be affected by the wire gauge/size (AWG)?

There is a pervasive myth in our industry that wire gauge does not affect loop performance (aside from tensile strength). This theory’s origin in likely the result of an informal test that was ran years ago that compared two 6’x6’ loops wrapped with different gauge wires. The loops in the test had little to no lead-in (the test does not specify), the results showed that there were slight differences in performance but it was negligible.  In our opinion the test had some obvious issues, such as using a small loop size, not including a lead-in run in the test, and not documenting how the readings were obtained, which call the results of the test into question.

What is most bizarre about this myth is its power to cause people to over look basic obvious electronic principles. It is understandable why anyone would want to believe that wire gauge doesn’t matter – you can save money by wrapping your loops out of higher gauge (thinner) wire!

Unfortunately, size does matter. The most basic explanation on why wire gauge matters is because the thinner a wire is (higher gauge) the more resistance there will be to the flow of current. More resistance means more energy loss, which means weaker/less reliable detections.  In fact many Department of Transportation (DOT) manuals instruct to never use wire gauges higher (thinner) than 16AWG when wrapping loops.  

But now that we have loosely covered why wire gauge matters, let’s get into a more in-depth explanation how wire gauge affects loop systems. To accomplish this we will compare popular wire gauge sizes for loops in this industry.

AWG stands for American Wire Gauge – the thicker a conductor is the lower its gauge number will be. The amount of copper in wire roughly doubles when comparing wires 3 gauges apart. So for example 17AWG wire has about double the amount of copper per foot as 20AWG. This means when comparing the gauges in the chart above 16 AWG has more than double the amount of copper as 20 AWG wire.

In the above chart we compare the resistance and breaking force of 16, 18, and 20 AWG wire. Not only is 16 AWG roughly 3 times stronger than 20AWG wire, it also has 86.6% less resistance than 20 AWG wire per foot. The much higher resistance of 20 AWG wire will decrease the performance of a loop and will result in a loop circuit being less sensitive, or loss of detection height/sensitivity that results in issues such as motorcycles not being detected.

The simple fact is that wire gauge affects the performance of inductance loops, this fact has been well documented in the traffic industry. For gates the difference in performance can be easily seen when comparing large loops or loops with long lead-in lengths. This is because the issues with the increased resistance of thinner gauge wire become more apparent as the amount of wire in a loop increases.

We decided to run a test on how wire gauge affects loops, in our testing we compared a loop wrapped with 16AWG wire and a loop wrapped with 24AWG wire. We found that the #24 AWG wire had 66% decrease in detection strength (performance) vs. the #16 AWG loop. For small loops such as a 6x6’with little or no lead-in the difference in performance might be negligible, but for larger loops or loops with longer lead-in it is significant. This test can be viewed on our website BDLoops.com

A major problem we see with the myth that wire gauge doesn’t matter is that installers often buy spools of #18-#20 AWG wire unaware that the wire should not be used for large loops or for loops with long lead-ins. Higher gauge (thinner) wire spools do not come with warnings explaining that they should only be used for small loops with very short lead-in lengths. Installers are often under the false impression that they should not wrap loops larger than a 6x20 because thinner gauge wire is so common in our industry. Nobody ever explains to the installers that they can wrap larger loops, or have longer lead-in if they use lower gauge (thicker) wire.

Knowing this, you might ask yourself why some loop manufacturers use larger gauge wire (thinner wire) in their loop design. Unfortunately that all comes down to dollars, generally half the cost of loop wire is based on the amount of copper per foot. When you purchase a spool of wire to make loops a 20AWG spool looks about the same as a 16 AWG spool when the wire is insulated. They both sell for about the same price (to installers).  Selling higher gauge spools of wire is simply more profitable.

The best advice we can give installers is not to skimp on the loop design with thinner (larger gauge) wire. We suggest a minimum of 16 AWG be used for best loop performance.


BD Loops is a manufacturer of preformed direct burial and saw-cut inductance loops for the gate, door, and parking industries. With over 15 years in business the quality of BD Loops is unparalleled. BD Loops products are available through over 400 distributors in the U.S. and Canada. BD Loops offers 46 standard preformed loop sizes, all standard and custom loop sizes are ready to be shipped the same day. The company has several letters of recommendation testifying their professionalism and design, and is a member of the following associations: AFA, IDA, NAFCA, IPI, NPA, CODA, and IMSA. Feel free to call BD Loop's knowledgeable staff with any questions about loops or their applications. While you are at the BDLoops.com website sign up for our free informative monthly installer newsletter. Use our distributor locator to find a distributor near you.